Scenarios
Four walk-throughs
Each follows the first-release plan: shadow, assist, then bounded control only after the agreed gates.
Nitrogen complex · ammonia loopSynthex◻ QUEUED
Energy per tonne on one synthesis unit
Baseline. Energy per tonne of ammonia, loop conversion, purge losses and catalyst duty, from the plant's own historian and energy meters over the first weeks of shadow mode.
Walk-through. Shadow mode reads the loop telemetry, the reformer and the compressor state and runs the conversion and energy models while the plant runs as usual. Once predicted conversion tracks the historian, assist mode proposes loop temperature and reaction moves inside the safety-reviewed envelope that bring energy per tonne down. The process engineer approves each move; corrections train the model. Purge and trip settings are never candidates; any loop move beyond the envelope waits for a named approver.
Gate. Conversion-prediction accuracy against the historian, then an energy-per-tonne reduction that justifies $22,000 per unit per month from verified savings.
Urea plant · granulatorGranulex◻ QUEUED
Granule size distribution and moisture on one granulator
Baseline. Granule size distribution variance, moisture, hardness, dust and recycle tonnes, from the plant's own granule analyzers, lab records and recycle metering.
Walk-through. Granvis cameras on the discharge and cooler belts feed size, shape and moisture models while the granulator runs on its usual curves. Assist mode proposes recycle-ratio, spray and bed-temperature moves, each rehearsed on the twin, that hold the distribution inside the band with less recycle. The process engineer's corrections are captured as per-product memory, so the next campaign starts from what the last one taught.
Gate. Distribution and moisture accuracy against the lab, then a dust and recycle reduction the plant can see on its own meters.
Nitrate plant · emissionsGranvis◻ QUEUED
Emissions excursions on a prill tower and reaction train
Baseline. CO2, NOx and ammonia-slip excursions, variance against permit limits and time from excursion to detection, from the plant's own emissions sensors and permit records.
Walk-through. Shadow mode fuses emissions sensors with historian and analyzer streams and compares predicted excursions to the recorded ones. Assist mode flags an excursion minutes ahead with the process state that is driving it and proposes the reaction or evaporation move that protects the margin. The permit limits are read and verified, never optimized against, and the HSE lead owns every response.
Gate. Excursion-prediction lead time and accuracy, with the permit margin untouched and the HSE lead trusting the alerts.
NPK plant · bagging lineBlendex◻ QUEUED
Nutrient ratio and bag weight on one blending and bagging line
Baseline. Nutrient-ratio conformance, segregation events, bag-weight giveaway, rework and claims, from assays, checkweighers and bagging records.
Walk-through. Shadow mode reads the dosing gates, the belt and the bagging line and compares predicted ratio and weight to assays and the checkweigher. Assist mode proposes dosing and anti-segregation moves and bag-weight trims inside the approved window. Robotic palletizing stays in perception and recommendation mode until the plant hazard review is done.
Gate. Ratio and weight accuracy against assay and checkweigher, then a rework and giveaway reduction the plant can verify.